For more information on our installation pricing click here.
Fire hose reel cabinet installation.
The automatic stop valve opens to provide full capacity within just two revolutions of the reel.
Hose reel placement is covered by the building code of australia bca.
We keep pricing simple and understandable.
It is not recommended that the hose reel is mounted at a height that will complicate easy maintenance re winding of the hose or make it difficult for a person of average.
Naffco cabinets are designed to accommodate fire hose reel fire fighting equipment and breeching inlet.
The recommended installation height for easy operation of a fire hose reel is such that the distance from the floor to the centre of the hose reel is 1 5m to 1 8m.
2016 nfpa 14 standard for the installation of standpipe and hose systems has the requirements in section 7 3 1 1.
Hose reel is not recommended.
The hose reel equipped with an automatic stop valve is mounted on the door which opens 180.
Installation must be carried out in accordance with as2441 2005.
Avoid having any obstructions around or near the hose reel assembly and the valve handwheel.
Hose reel cabinets fire extinguisher cabinets and log book cabinets to name just a few.
Where the fire hose reel is to be installed in an external situation or an aggressive environment it shall be protected by a cabinet or other suitable means.
Hose reels should only be connected to a.
Fire hose reel cabinets are manufactured to comply with bsen 671 1 standard and breeching inlet cabinets are manufactured to comply to bs 5041 5 standard.
Fire cabinet is designed for theft and vandalism protection in public areas and buildings to safely store fire equipment such as fire hose rack assembly fire hose reel and fire extinguisher.
It is a steel box mounted at any place for firefighting convenience with simple installation light weight and small occupation.
Installation of hose reel for recessed fire hose cabinets the hose reel shall be installed inside the fire cabinet utilizing the existing brackets in the cabinet.
When installing fire hose reels our plumbers consider the following.
Maintain at least 2m clearance around the spindle and 100mm from the handwheel.
We can provide a complete fire extinguisher and safety cabinet installation service at very competitive rates using our qualified technicians.
The reel can easily be removed from the cabinet during installation so that one man alone can install the cabinet.
Hose connections and hose stations must be unobstructed and must be located not less than 3 ft 9 m or more than 5 ft 1 5 m above the floor.
Location mounting requirements a each hose reel shall be located in a readily accessible position and its location shall be clearly indicated.
Fire cabinets also help to protect the equipment inside from dirt and rubbish.
There are many types of cabinets available.
The hose reel is suitable for use in.
As part of your fire emergency training the fire hose reel installation requirements and operating instructions should be covered.