The minimum outdoor airflow rate shall be determined in accordance with section 403 3.
Fbc attic ventilation.
In a balanced ventilation configuration ambient outside air enters into the attic space via soffit or eave vents.
Ventilation supply systems shall be designed to deliver the.
Ashrae detailed practices for 3 climatic conditions.
Lowering the temperature in the attic can help reduce air conditioning energy costs and roof deck temperature optimize the service life of a roof covering and minimize ice damming.
A minimum 5 vent termination height above a gas fired air handler must be maintained.
403 2 outdoor air required.
Proper attic ventilation consists of a balance between air intake at your eaves soffits or fascias and air exhaust at or near your roof ridge.
Attic ventilation serves two main functions.
The international codes i codes are the widely accepted comprehensive set of model codes used in the us and abroad to help ensure the engineering of safe sustainable affordable and resilient structures.
A 120 volt receptacle outlet must be installed in the attic and within 25 of the equipment needing service fbcm 306 3 1 nec 210 63 k.
Requiring service with the lighting outlet switch at the attic access.
Uninhabited spaces such as crawl spaces and attics shall be provided with natural ventilation openings as required by the florida building code building or shall be provided with a mechanical exhaust and supply air system.
Openings for ventilation having a least dimension of not less than 1 16 inch 1 6 mm and not more than 1 4 inch 6 4 mm shall be permitted.
Opening fbcm 306 4 1 nec 210 70 fbcrm1305 1 3 1 j.
Warm humid new fbc codes allow construction practices which do not require attic to be ventilated.
The international code council icc is a non profit organization dedicated to developing model codes and standards used in the design build and compliance process.
Attic ventilation works on the principle that heated air naturally rises primarily utilizing two types of vents.
Intake vents located at the lowest part of the roof under the eaves allow cool.
See also section 503 2 10 6 of the florida building code energy conservation.
This air passes through the attic space where it displaces warm moisture laden air which in turn exits the attic via vents at or near the top of the space being vented.
Exterior openings into the attic space of any building intended for human occupancy shall be protected to prevent the entry of birds squirrels rodents snakes and other similar creatures.
Tem to convey ventilation air shall be designed and installed in accordance with chapter 6.
Federal housing authority recommends a minimum of at least 1 square foot of attic ventilation evenly split between intake and exhaust for every 300 square feet of attic floor space.